Author: rjung
Date: Wed Mar 4 16:39:19 2009
New Revision: 750069
URL: http://svn.apache.org/viewvc?rev=750069&view=rev
Log:
Use port == 0 as a disable indicator instead
of addr_sequence. That makes it more consistent.
Modified:
tomcat/connectors/trunk/jk/native/common/jk_lb_worker.c
Modified: tomcat/connectors/trunk/jk/native/common/jk_lb_worker.c
URL:
http://svn.apache.org/viewvc/tomcat/connectors/trunk/jk/native/common/jk_lb_worker.c?rev=750069&r1=750068&r2=750069&view=diff
==============================================================================
--- tomcat/connectors/trunk/jk/native/common/jk_lb_worker.c (original)
+++ tomcat/connectors/trunk/jk/native/common/jk_lb_worker.c Wed Mar 4 16:39:19
2009
@@ -1560,7 +1560,7 @@
if (p->lb_workers[i].worker->type == JK_AJP13_WORKER_TYPE ||
p->lb_workers[i].worker->type == JK_AJP14_WORKER_TYPE) {
ajp_worker_t *aw = (ajp_worker_t
*)p->lb_workers[i].worker->worker_private;
- if (!aw->addr_sequence) {
+ if (aw->port == 0) {
p->lb_workers[i].activation = JK_LB_ACTIVATION_STOPPED;
}
}
---------------------------------------------------------------------
To unsubscribe, e-mail: [email protected]