https://issues.apache.org/bugzilla/show_bug.cgi?id=55181
Bug ID: 55181
Summary: Ping and Pong messages should have identical
application data
Product: Tomcat 8
Version: trunk
Hardware: PC
Status: NEW
Severity: normal
Priority: P2
Component: Catalina
Assignee: [email protected]
Reporter: [email protected]
Created attachment 30520
--> https://issues.apache.org/bugzilla/attachment.cgi?id=30520&action=edit
PingPongMessages.patch
As described in RFC 6455 Ping and Pong should have identical application data.
http://tools.ietf.org/html/rfc6455#section-5.5.3
Current implementation can return application data ByteBuffer with extra bytes
hence have different length from "ping" message which means that those are not
identical.
Here is a patch + test case
cheers
niki
--