https://issues.apache.org/jira/browse/TUBEMQ-66?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
 ]

Guo Jiwei updated TUBEMQ-66:
----------------------------
    Description: 
1. TubeSingleSessionFactory could not shutdown
 due to we increase referenceCounter one more time after first constructor 
method:
{code:java}
public TubeSingleSessionFactory(final TubeClientConfig tubeClientConfig) throws 
TubeClientException {
    if (referenceCounter.incrementAndGet() == 1) {
        RpcConfig config = 
TubeClientConfigUtils.getRpcConfigByClientConfig(tubeClientConfig, true);
        clientFactory.configure(config);
        //#1
        referenceCounter.incrementAndGet();
        baseSessionFactory = new TubeBaseSessionFactory(clientFactory, 
tubeClientConfig);
    }
}
{code}
We should remove #1

  was:
1.  TubeSingleSessionFactory could not shutdown
 due to we increase referenceCounter after first constructor method:
{code:java}
public TubeSingleSessionFactory(final TubeClientConfig tubeClientConfig) throws 
TubeClientException {
    if (referenceCounter.incrementAndGet() == 1) {
        RpcConfig config = 
TubeClientConfigUtils.getRpcConfigByClientConfig(tubeClientConfig, true);
        clientFactory.configure(config);
        //#1
        referenceCounter.incrementAndGet();
        baseSessionFactory = new TubeBaseSessionFactory(clientFactory, 
tubeClientConfig);
    }
}
{code}
{code:java}
public void shutdown() throws TubeClientException {
        if (referenceCounter.decrementAndGet() > 0) {
            return;
        }
        baseSessionFactory.shutdown();
        clientFactory.shutdown();
    }
{code}
We can fix it only remove #1,  but I think this is not the best implementation 
for TubeSingleSessionFactory. How about do it like below :
{code:java}
private static final AtomicBoolean isStarted = new AtomicBoolean(false);
    private static TubeBaseSessionFactory baseSessionFactory;


    public TubeSingleSessionFactory(final TubeClientConfig tubeClientConfig) 
throws TubeClientException {
        if (isStarted.compareAndSet(false, true)) {
            RpcConfig config = 
TubeClientConfigUtils.getRpcConfigByClientConfig(tubeClientConfig, true);
            clientFactory.configure(config);
            baseSessionFactory = new TubeBaseSessionFactory(clientFactory, 
tubeClientConfig);
        }
    }

    @Override
    public void shutdown() throws TubeClientException {
        if (isStarted.compareAndSet(true, false)) {
            baseSessionFactory.shutdown();
            clientFactory.shutdown();
        }
    }
{code}


> TubeSingleSessionFactory shutdown bug
> -------------------------------------
>
>                 Key: TUBEMQ-66
>                 URL: https://issues.apache.org/jira/browse/TUBEMQ-66
>             Project: Apache TubeMQ
>          Issue Type: Bug
>            Reporter: Guo Jiwei
>            Assignee: Guo Jiwei
>            Priority: Normal
>              Labels: pull-request-available
>          Time Spent: 20m
>  Remaining Estimate: 0h
>
> 1. TubeSingleSessionFactory could not shutdown
>  due to we increase referenceCounter one more time after first constructor 
> method:
> {code:java}
> public TubeSingleSessionFactory(final TubeClientConfig tubeClientConfig) 
> throws TubeClientException {
>     if (referenceCounter.incrementAndGet() == 1) {
>         RpcConfig config = 
> TubeClientConfigUtils.getRpcConfigByClientConfig(tubeClientConfig, true);
>         clientFactory.configure(config);
>         //#1
>         referenceCounter.incrementAndGet();
>         baseSessionFactory = new TubeBaseSessionFactory(clientFactory, 
> tubeClientConfig);
>     }
> }
> {code}
> We should remove #1



--
This message was sent by Atlassian Jira
(v8.3.4#803005)

Reply via email to