Lou DeGenaro created UIMA-4902:
----------------------------------

             Summary: DUCC Job Driver (JD) add programmability feature to 
built-in error handler
                 Key: UIMA-4902
                 URL: https://issues.apache.org/jira/browse/UIMA-4902
             Project: UIMA
          Issue Type: Improvement
          Components: DUCC
            Reporter: Lou DeGenaro
            Assignee: Lou DeGenaro
             Fix For: 2.1.0-Ducc


The Job Driver built-in error handler is not readily "programmable".  

A desired feature is to specify, per Job, the number of work item time-outs 
allowed for each work item.  Presently, the number of retrys per work item 
time-out is 0.  The default remains 0.

Allow users job submissions to specify for driver_jvm_args 
-DJobDriverErrorHandlerMaximumNumberOfTimeoutRetrysPerWorkItem=N, where N is an 
integer.  If a work item times-out, it will be counted.  If the number of 
retrys for that work item does not exceed the specified integer, it will be 
retried, else it will be a work item error.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)