https://issues.apache.org/jira/browse/ZOOKEEPER-2503?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15410608#comment-15410608
]
Flavio Junqueira commented on ZOOKEEPER-2503:
---------------------------------------------
We require it in the processing of session ids, here are the two references I
got:
{noformat}
nextSessionId = SessionTrackerImpl.initializeNextSession(this.serverId);
public static long initializeNextSession(long id) {
long nextSid = 0;
nextSid = (System.currentTimeMillis() << 24) >>> 8;
nextSid = nextSid | (id <<56);
return nextSid;
}
{noformat}
and in LeaderSessionTracker:
{noformat}
// Returns the serverId from the sessionId (the high order byte)
public static long getServerIdFromSessionId(long sessionId) {
return sessionId >> 56;
}
{noformat}
I couldn't find it anywhere else.
> Inconsistency between myid documentation and implementation
> -----------------------------------------------------------
>
> Key: ZOOKEEPER-2503
> URL: https://issues.apache.org/jira/browse/ZOOKEEPER-2503
> Project: ZooKeeper
> Issue Type: Bug
> Components: server
> Affects Versions: 3.4.9, 3.5.2
> Reporter: Michael Han
> Fix For: 3.5.3, 3.4.10
>
>
> In ZK documentation, we have:
> "The myid file consists of a single line containing only the text of that
> machine's id. So myid of server 1 would contain the text "1" and nothing
> else. The id must be unique within the ensemble and should have a value
> between 1 and 255."
> This however is not enforced in code, which should be fixed either in
> documentation that we remove the restriction of the range 1-255 or in code we
> enforce such constraint.
> Discussion thread:
> http://zookeeper-user.578899.n2.nabble.com/Is-myid-actually-limited-to-1-255-td7581270.html
--
This message was sent by Atlassian JIRA