Hi,

After some problems sending UDH over a Siemens M20 modem. I happen to see
what at+cnmi actually meant.
In the Siemens M20 documentation on
http://www.ic.siemens.com/Daten/Produkt/2000/12/14/223050m20_td.pdf (on page
103)
it is indicated that the number "1" in at+cnmi=1,2,0,0,0 will mean that
incoming messages will be discarded?
Would it not be better to use at+cnmi=2,2,0,0,0?

<Mode>
1 Discard indication and reject new received message unsolicited result
codes
when TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward
them directly to the TE.
2 Buffer unsolicited result codes in the TA when TA-TE link is reserved
(e.g.
in on-line data mode) and flush them to the TE after reservation. Otherwise
forward them directly to the TE.

Med Venlig Hilsen / With Best Regards

Steffen Lindemann
TDC Mobile International A/S
tel.: +45 40 25 39 81
e-mail: [EMAIL PROTECTED]