Bjoern Buettner wrote: > > I've configured the kannel WAP GW- in version "cvs 30-dec.2001". > > Previous version of Kannel WAP was 1.0.5, it worked very fine. > With the new version, we have some problems with SIEMENS S35 Phones. > If I try to connect with the SIEMENS S35 to the gw, following error appears. > > "2002-01-31 13:19:12 [1] WARNING: Unknown content type 0x202." > "2002-01-31 13:19:12 [1] WARNING: Skipping faulty header." > > Is it a problem with Kannel or the SIEMENS S35 WAP Browser ?
I guess this is a problem with the user agent of Siemens S35, the openwave.com (aka phone.com) browser. The browser seems to set headers that are explicitly out of the official specification and hence Kannel detects it as unknown content types! AFAIK, phone.com did this to enable properietary functionality with their own phone.com WAP GW. So the WML deck should be displayed using kannel, but you still get the warnings in the log. There has been a thread on the mailing list if we should figure out what this headers are used to mean and if we would try to support them. But as you may imagine this would mean getting onto to properietary line of phone.com and the group das declined to do so. Stipe [EMAIL PROTECTED] ------------------------------------------------------------------- Wapme Systems AG M�nsterstr. 248 40470 D�sseldorf Tel: +49-211-74845-0 Fax: +49-211-74845-299 E-Mail: [EMAIL PROTECTED] Internet: http://www.wapme-systems.de ------------------------------------------------------------------- wapme.net - wherever you are
