"S.Ramakrishnan" wrote:
> 
> Hi!
>     Just wanted to know where we can get SMPP to EMI protocol
>  Mapping..
> Any RFC or Document on that?

no, there is no RFC or document that would cover that. At least I
don't know such thing.

You may be able to use SMPP server side logic to fead an EMI client
side again. 

Basically that is what we do with our smppbox, an SMPP v3.4 server
based on Kannel. We feed the Kannel abstracted msg structure again to
bearerbox and there you can have an UCP/EMI link to continue the
delivery.