Hi, I have solved all my problems - bitmaps and midi files are now working fine. Thanks Illimar for the help.
Next week I will try to write some tutorial based on Siemens and maybe EMS smart messaging. I put Siemens OTA spec in http://soften.ktu.lt/~menulis/OTA_Specification_Release1.0.2.pdf but I'm sure, that it could be found somewhere in siemens.com (I found it myself some time ago). By the way, in my opinion, there is a mistake in given example about the total size of bitmap (103x8 != 750). If you have any related questions - please ask ;) Have a nice weekend, guys. regards, Dziugas Baltrunas On Fri, 18 Jul 2003, [ISO-8859-1] Aarno Syvänen wrote: > Do you have ota spec for siemens ? If you do, is it public ? > > Aarno > > On Monday, July 14, 2003, at 10:40 AM, Dziugas Baltrunas wrote: > > > Hi list, > > > > I remember that there was an intereset in mailing list about Siemens > > SEO, > > especially Illimar Reinbusch, who reported that is's working for him > > (http://www.mail-archive.com/[EMAIL PROTECTED]/msg00221.html) > > > > here is my code (72x14 bitmap, Windows BMP format): > > > > http://smsbox.m-1.lt:13013/cgi-bin/ > > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// > > SEO%01%6C%00%00%00%00%00%01%00%03%00%E6%00%00%00%03bmp%07683.bmp%42%4d% > > e6%00%00%00%00%00%00%00%3e%00%00%00%28%00%00%00%48%00%00%00%0e%00%00%00 > > %01%00%01%00%00%00%00%00%a8%00%00%00%6d%0b%00%00%6d%0b%00%00%02%00%00%0 > > 0%02%00%00%00%00%00%00%00%ff%ff%ff%00%fe%3f%d8%f7%f7%ef%db%fc%7f%75%65% > > 73%fd%df%b7%f7%f7%ef%ed%fb%bf%6c%73%27%fb%bf%36%e9%c3%97%6d%fd%df%44%5f > > %4f%fb%7f%6f%6e%00%70%c6%fe%df%73 > > http://smsbox.m-1.lt:13013/cgi-bin/ > > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// > > SEO%01%6C%00%00%00%00%00%02%00%03%00%E6%00%00%00%03bmp%07683.bmp%75%62% > > cb%bc%67%9f%81%fb%96%3d%d3%75%65%73%b5%c1%63%bf%81%fd%f6%83%ad%6c%73%20 > > %73%eb%6d%7f%7e%fe%e6%d7%ce%24%73%65%73%eb%67%7f%bd%fe%e6%d7%ce%74%3b%0 > > a%b5%c1%66%f0%18%0f%66%83%ad%76%2c%24%cb%bc%66%e6%3c%67%46%3d%d3%5f%3b% > > 0a%fb%7f%66%e6%7e%67%76%fe%df%20%24%76%fb%bf%b6%f0%eb%0f%6d%fd%df%76%29 > > %20%fd%df%b6%c3%d5%c3%6d%fb%bf%20 > > http://smsbox.m-1.lt:13013/cgi-bin/ > > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=// > > SEO%01%6C%00%00%00%00%00%03%00%03%00%E6%00%00%00%03bmp%07683.bmp%26%26% > > fe%3f%da%ff%b6%ff%5b%fc%7f%29%3b%0a%00%00%00%00%00%00%00%00%00%00%00%00 > > %00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%0 > > 0%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00% > > 00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00 > > %00%00%00%00%00%00%00%00%00%00%00 > > > > everything is done by example in contrib/web/sendsms.php except the > > last > > message, because, acording to "OTA Specification release", last SM has > > to > > be filled with zeros, i.e. 0x00, so "Data size" for every SM segment > > must > > be the same (here it's 140 - 22 - 3 - length(683.bmp) = 108 octets). > > > > when i try to send these messages to Siemens ME45, phone keeps silent > > and > > here is no asking for indication. > > > > what might be wrong here? Illimar, are you alive?! ;) > > > > regards, > > Dziugas Baltrunas > > >