Hi,

I have solved all my problems - bitmaps and midi files are now working
fine. Thanks Illimar for the help.

Next week I will try to write some tutorial based on Siemens and maybe
EMS smart messaging.

I put Siemens OTA spec in
http://soften.ktu.lt/~menulis/OTA_Specification_Release1.0.2.pdf

but I'm sure, that it could be found somewhere in siemens.com (I found it
myself some time ago). By the way, in my opinion, there is a mistake in
given example about the total size of bitmap (103x8 != 750).

If you have any related questions - please ask ;)

Have a nice weekend, guys.

regards,
Dziugas Baltrunas

On Fri, 18 Jul 2003, [ISO-8859-1] Aarno Syvänen wrote:

> Do you have ota spec for siemens ? If you do, is it public ?
>
> Aarno
>
> On Monday, July 14, 2003, at 10:40 AM, Dziugas Baltrunas wrote:
>
> > Hi list,
> >
> > I remember that there was an intereset in mailing list about Siemens
> > SEO,
> > especially Illimar Reinbusch, who reported that is's working for him
> > (http://www.mail-archive.com/[EMAIL PROTECTED]/msg00221.html)
> >
> > here is my code (72x14 bitmap, Windows BMP format):
> >
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%01%00%03%00%E6%00%00%00%03bmp%07683.bmp%42%4d%
> > e6%00%00%00%00%00%00%00%3e%00%00%00%28%00%00%00%48%00%00%00%0e%00%00%00
> > %01%00%01%00%00%00%00%00%a8%00%00%00%6d%0b%00%00%6d%0b%00%00%02%00%00%0
> > 0%02%00%00%00%00%00%00%00%ff%ff%ff%00%fe%3f%d8%f7%f7%ef%db%fc%7f%75%65%
> > 73%fd%df%b7%f7%f7%ef%ed%fb%bf%6c%73%27%fb%bf%36%e9%c3%97%6d%fd%df%44%5f
> > %4f%fb%7f%6f%6e%00%70%c6%fe%df%73
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%02%00%03%00%E6%00%00%00%03bmp%07683.bmp%75%62%
> > cb%bc%67%9f%81%fb%96%3d%d3%75%65%73%b5%c1%63%bf%81%fd%f6%83%ad%6c%73%20
> > %73%eb%6d%7f%7e%fe%e6%d7%ce%24%73%65%73%eb%67%7f%bd%fe%e6%d7%ce%74%3b%0
> > a%b5%c1%66%f0%18%0f%66%83%ad%76%2c%24%cb%bc%66%e6%3c%67%46%3d%d3%5f%3b%
> > 0a%fb%7f%66%e6%7e%67%76%fe%df%20%24%76%fb%bf%b6%f0%eb%0f%6d%fd%df%76%29
> > %20%fd%df%b6%c3%d5%c3%6d%fb%bf%20
> > http://smsbox.m-1.lt:13013/cgi-bin/
> > sendsms?user=test&pass=test&from=xxx&smsc=xxx&to=xxx&coding=2&text=//
> > SEO%01%6C%00%00%00%00%00%03%00%03%00%E6%00%00%00%03bmp%07683.bmp%26%26%
> > fe%3f%da%ff%b6%ff%5b%fc%7f%29%3b%0a%00%00%00%00%00%00%00%00%00%00%00%00
> > %00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%0
> > 0%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%
> > 00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00%00
> > %00%00%00%00%00%00%00%00%00%00%00
> >
> > everything is done by example in contrib/web/sendsms.php except the
> > last
> > message, because, acording to "OTA Specification release", last SM has
> > to
> > be filled with zeros, i.e. 0x00, so "Data size" for every SM segment
> > must
> > be the same (here it's 140 - 22 - 3 - length(683.bmp) = 108 octets).
> >
> > when i try to send these messages to Siemens ME45, phone keeps silent
> > and
> > here is no asking for indication.
> >
> > what might be wrong here? Illimar, are you alive?! ;)
> >
> > regards,
> > Dziugas Baltrunas
> >
>