as no objections were there, commited to cvs.

On Monday 12 January 2004 15:08, Alexander Malysh wrote:
> Hi all,
>
> attached you can find patch that adds 2 new options for smsc_at:
> max-error-count and reset-string. For description of those see userguide
> changes inside of the patch.
> This patch adds also properly device reconnections and some fixes here and
> there.
>
> P.S. This patch was generated based on smsc_at from centrium tree and is
> used since at least 3 months w/o any problems.
>
> Comments and votes please!
>
>  doc/userguide/userguide.xml |   16     16 +    0 -     0 !
>  gw/smsc/smsc_at.c           |  105     79 +    26 -    0 !
>  gw/smsc/smsc_at.h           |    4     3 +     1 -     0 !
>  gwlib/cfg.def               |    2     2 +     0 -     0 !
>  4 files changed, 100 insertions(+), 27 deletions(-)

-- 
Best regards / Mit besten Gr��en aus D�sseldorf