Hi,

you're right it's a bug and this is known one.
for example see Thread with subject:
[Delivery reports not working in latest CVS using SMPP 3.4 to logica SMSC]

On Friday 20 February 2004 16:43, Paul Keogh wrote:
> I think there is a bug in the smpp_pdu_pack() function
> when packing optional parameters.
>
> The tag_id and opt_len are not converted from host to
> network byte ordering as they should be for a byte oriented
> wire encoding.
>
> The corresponding unpack function works fine.

-- 
Best regards / Mit besten Gr��en aus D�sseldorf