sorry, but still the same:
+ case 0:
+ /*
+ * Default the code to 0 then when you extract the value from the
+ * modem response message and no code is found, 0 will result.
+ */
+ return "Modem returned ERROR but no error code - possibly
unsupported or invalid command?";
indents are 4 spaces instead of 2.
Thanks,
Alex
Am 17.06.2009 um 13:24 schrieb Vincent CHAVANIS:
yep, you're right.
new file attached.
without blank comments, and text cleaned.
Vincent.
Alexander Malysh a écrit :
Hi Vincent,
some comments:
+ error(0, "AT2[%s]: [%d/%ld] Initialization of device
failed.", octstr_get_cstr(privdata->name),
+ error_count, privdata->max_error_count);
this is not very informative for kannel user. Please write out
something like Init failed errors X from max errors X.
please kill comments like this:
+ /*
+ */
please fix indentation, we use 4 spaces...
Thanks,
Alex
Am 17.06.2009 um 12:56 schrieb Vincent CHAVANIS:
From an old thread (http://www.mail-archive.com/[email protected]/msg07693.html
)
Alex moved the at2_error_string into smsc_at.c
2004-09-18 Alexander Malysh <amalysh at kannel.org>
* gw/smsc/smsc_at.c: added new function 'at2_error_string' and
teached
smsc_at to use it.
But some error codes are missing.
1472:2009-06-16 16:00:59.0442 [2255] [8] ERROR: AT2[WAVECOM]:
Generic error: +CME ERROR: 515
2710:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: CMS
ERROR: +CMS ERROR: 513
2711:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: CMS
ERROR: Error number unknown. Ask google and add it. (513)
Each code is more or less detailled on comments
I think this should be left as it as there are no documentation on
it.
This patch also prints the counter before the reset-string.
Vincent.
<smsc_at2_error_string_patch_v2.txt>