sorry, but still the same:

+    case 0:
+      /*
+       * Default the code to 0 then when you extract the value from the
+       * modem response message and no code is found, 0 will result.
+       */
+ return "Modem returned ERROR but no error code - possibly unsupported or invalid command?";

indents are 4 spaces instead of 2.

Thanks,
Alex

Am 17.06.2009 um 13:24 schrieb Vincent CHAVANIS:

yep, you're right.

new file attached.
without blank comments, and text cleaned.

Vincent.

Alexander Malysh a écrit :
Hi Vincent,
some comments:
+ error(0, "AT2[%s]: [%d/%ld] Initialization of device failed.", octstr_get_cstr(privdata->name),
+                     error_count, privdata->max_error_count);
this is not very informative for kannel user. Please write out something like Init failed errors X from max errors X.
please kill comments like this:
+      /*
+       */
please fix indentation, we use 4 spaces...
Thanks,
Alex
Am 17.06.2009 um 12:56 schrieb Vincent CHAVANIS:

From an old thread (http://www.mail-archive.com/[email protected]/msg07693.html )
Alex moved the at2_error_string into smsc_at.c

2004-09-18 Alexander Malysh <amalysh at kannel.org>
* gw/smsc/smsc_at.c: added new function 'at2_error_string' and teached
    smsc_at to use it.

But some error codes are missing.
1472:2009-06-16 16:00:59.0442 [2255] [8] ERROR: AT2[WAVECOM]: Generic error: +CME ERROR: 515 2710:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: CMS ERROR: +CMS ERROR: 513 2711:2009-06-16 23:35:40.0142 [2255] [8] ERROR: AT2[WAVECOM]: CMS ERROR: Error number unknown. Ask google and add it. (513)

Each code is more or less detailled on comments
I think this should be left as it as there are no documentation on it.

This patch also prints the counter before the reset-string.

Vincent.

<smsc_at2_error_string_patch_v2.txt>


Reply via email to