What bothers me a bit about this patch is that messages we don't receive ack for are going to stay in memory forever, well, as long the boxc is alive. A proper timeout mechanism would be a nice bonus.
2010/8/2 Rene Kluwen <[email protected]>: > Here is a more advanced patch. Messages to bearerbox are acked, once the > deliver_sm_resp pdu is in. > Also submit_sm pdu's get their responses, after bearerbox has acked the > message. And if not, a failure notice is returned. > Before, message acks were given right away, without checking for failure or > rejection. > > Tomasz: Would it be possible for you to test this patch in your environment? > > Victor: Would you review for stupidities? > > Comments are welcome. > > == Rene > > -- Best regards, Victor Luchitz