From: Martin Homuth-Rosemann <[email protected]> Correct at least one of the incorrect specs for a national instrument data acquisition card DAQCard-6024E. This card has only four different gain settings (+-10V, +-5V, +-0.5V, +-0.05V).
Signed-off-by: Martin Homuth-Rosemann <[email protected]> Cc: stable <[email protected]> Signed-off-by: Greg Kroah-Hartman <[email protected]> --- drivers/staging/comedi/drivers/ni_mio_cs.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-) diff --git a/drivers/staging/comedi/drivers/ni_mio_cs.c b/drivers/staging/comedi/drivers/ni_mio_cs.c index cedb02d..3a46f0c 100644 --- a/drivers/staging/comedi/drivers/ni_mio_cs.c +++ b/drivers/staging/comedi/drivers/ni_mio_cs.c @@ -123,7 +123,7 @@ static const struct ni_board_struct ni_boards[] = { .adbits = 12, .ai_fifo_depth = 1024, .alwaysdither = 0, - .gainlkup = ai_gain_16, + .gainlkup = ai_gain_4, .ai_speed = 5000, .n_aochan = 2, .aobits = 12, -- 1.7.1 _______________________________________________ devel mailing list [email protected] http://driverdev.linuxdriverproject.org/mailman/listinfo/devel