From: Martin Homuth-Rosemann <[email protected]>

Correct at least one of the incorrect specs for a national instrument
data acquisition card DAQCard-6024E. This card has only four different
gain settings (+-10V, +-5V, +-0.5V, +-0.05V).

Signed-off-by: Martin Homuth-Rosemann <[email protected]>
Cc: stable <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
---
 drivers/staging/comedi/drivers/ni_mio_cs.c |    2 +-
 1 files changed, 1 insertions(+), 1 deletions(-)

diff --git a/drivers/staging/comedi/drivers/ni_mio_cs.c 
b/drivers/staging/comedi/drivers/ni_mio_cs.c
index cedb02d..3a46f0c 100644
--- a/drivers/staging/comedi/drivers/ni_mio_cs.c
+++ b/drivers/staging/comedi/drivers/ni_mio_cs.c
@@ -123,7 +123,7 @@ static const struct ni_board_struct ni_boards[] = {
         .adbits = 12,
         .ai_fifo_depth = 1024,
         .alwaysdither = 0,
-        .gainlkup = ai_gain_16,
+        .gainlkup = ai_gain_4,
         .ai_speed = 5000,
         .n_aochan = 2,
         .aobits = 12,
-- 