Remove the private range, range_ni_S_ai_6143, in this driver and use
the comedi provided range_bipolar5 instead.

Signed-off-by: H Hartley Sweeten <hswee...@visionengravers.com>
Cc: Ian Abbott <abbo...@mev.co.uk>
Cc: Greg Kroah-Hartman <gre...@linuxfoundation.org>
---
 drivers/staging/comedi/drivers/ni_mio_common.c | 7 +------
 1 file changed, 1 insertion(+), 6 deletions(-)

diff --git a/drivers/staging/comedi/drivers/ni_mio_common.c 
b/drivers/staging/comedi/drivers/ni_mio_common.c
index ca52b75..0f8d05c 100644
--- a/drivers/staging/comedi/drivers/ni_mio_common.c
+++ b/drivers/staging/comedi/drivers/ni_mio_common.c
@@ -189,11 +189,6 @@ static const struct comedi_lrange range_ni_M_ai_628x = { 
7, {
                                                             }
 };
 
-static const struct comedi_lrange range_ni_S_ai_6143 = { 1, {
-                                                            RANGE(-5, +5),
-                                                            }
-};
-
 static const struct comedi_lrange range_ni_E_ao_ext = { 4, {
                                                            RANGE(-10, 10),
                                                            RANGE(0, 10),
@@ -210,7 +205,7 @@ static const struct comedi_lrange *const ni_range_lkup[] = {
        [ai_gain_611x] = &range_ni_E_ai_611x,
        [ai_gain_622x] = &range_ni_M_ai_622x,
        [ai_gain_628x] = &range_ni_M_ai_628x,
-       [ai_gain_6143] = &range_ni_S_ai_6143
+       [ai_gain_6143] = &range_bipolar5
 };
 
 static int ni_dio_insn_config(struct comedi_device *dev,
-- 
1.8.1.4

_______________________________________________
devel mailing list
devel@linuxdriverproject.org
http://driverdev.linuxdriverproject.org/mailman/listinfo/devel

Reply via email to