There is an infrequent problem with the XO-1.5 B2 prototypes where they may not power-up properly.
This would be indicated by the EC rapidly flashing the battery LED red. It then tries to power up the laptop again, frequenly succeeding. This will appear as a flash or two of the red battery LED, followed by a normal boot. In an extreme case, it might stay that way for a while. This is being tracked as #9761 --- please add your reports to that ticket. This is likely due to a couple of leakage problems that we are finishing up. We hunt them down on each build, but other ECOs have a way of creating new ones. Cheers, wad _______________________________________________ Devel mailing list [email protected] http://lists.laptop.org/listinfo/devel