On Thu, Sep 22, 2011 at 06:35:06PM -0500, Jerry Vonau wrote: > On Fri, 2011-09-23 at 08:41 +1000, James Cameron wrote: > > Compare the manufacturing tags. The definition of selftest in the > > /switches vocabulary depends on the values of manufacturing tags. > > > > Thanks, that explains the XO-1.5, I was playing with adding the missing > mfg-tags on replacement motherboards, it's caused by having the TS key > set to RUNIN. Does the XO-1.75 have this test? The TS key is set to > SHIP, shouldn't the test return OKAY/FAIL like on the XO-1.5?
No, the "test /switches" test on XO-1.75 does not test the temperature rise of the CPU. When Q4B10 is released, a thermal sensor watchdog reset will be enabled, which will reset and then power down the unit if the CPU temperature exceeds 85C. This will occur in OFW or Linux. "watch-thermal" will be available to display the thermal conditions. "test-thermal" will be available to test the mechanism by lowering the threshold temperature to a few degrees above the current CPU temperature. -- James Cameron http://quozl.linux.org.au/ _______________________________________________ Devel mailing list [email protected] http://lists.laptop.org/listinfo/devel