Thanks for the patch. This is against the v1.2 series INI file; does
it also apply to "infinipath 1" in the v1.3 series INI file?
https://svn.open-mpi.org/trac/ompi/browser/trunk/ompi/mca/btl/openib/mca-btl-openib-device-params.ini
On Aug 12, 2008, at 5:29 PM, Ralph Campbell wrote:
Roland noticed that the QLogic HCA driver was using the PCIe
vendor ID for the ibv_query_device so the IEEE OUI value is
now used. This means the config file should recognize the
vendor ID value 0x1175 too.
Signed-off-by: Ralph Campbell <ralph.campb...@qlogic.com>
--- ompi/mca/btl/openib/mca-btl-openib-hca-params.ini.old 2008-06-17
11:54:08.000000000 -0700
+++ ompi/mca/btl/openib/mca-btl-openib-hca-params.ini 2008-08-12
14:20:07.542762000 -0700
@@ -126,7 +126,7 @@ use_eager_rdma = 1
mtu = 2048
[QLogic InfiniPath]
-vendor_id = 0x1fc1,0x1077
+vendor_id = 0x1fc1,0x1077,0x1175
vendor_part_id = 16,29216
use_eager_rdma = 1
mtu = 4096
_______________________________________________
devel mailing list
de...@open-mpi.org
http://www.open-mpi.org/mailman/listinfo.cgi/devel
--
Jeff Squyres
Cisco Systems