Hello,
Before implementing failover over ob1, I first tried to make pml dr work
and it did not on systems with multiple btl modules for a same btl
component (systems with 2 or more HCA or multi-port HCA for example).
This was due to bml r2 removing the unique btl component progress when
removing a btl module. Then, the remaining btl module was no longer
progressed.
I managed to get dr work after fixing that but poor performances made me
switch to ob1.
Mouhamed
Ralph Castain a écrit :
Hasn't worked in years, that I've heard of...
On Oct 5, 2010, at 6:56 PM, Jeff Squyres wrote:
Do we know if dr in the 1.5 tree works at all? Should it be removed?
--
Jeff Squyres
jsquy...@cisco.com
For corporate legal information go to:
http://www.cisco.com/web/about/doing_business/legal/cri/
_______________________________________________
devel mailing list
de...@open-mpi.org
http://www.open-mpi.org/mailman/listinfo.cgi/devel
_______________________________________________
devel mailing list
de...@open-mpi.org
http://www.open-mpi.org/mailman/listinfo.cgi/devel