this error message comes from ompio, the split collective are not properly implemented at this point in time, they are basically just a printf statement. Once I have the non-blocking collectives re-enabled, it should be trivial add these interfaces to the list as well.

That being said, since I spent quite some time debugging the I/O tests in mpi_test_suite, I would recommend *not* to use that for I/O validation. I found some fundamental mistakes in the test suite, (e.g. writing with a file view, reading back without the file view and assuming that the byte pattern is the same) that I can not easily fix.

Thanks
Edgar

On 3/6/2015 12:03 PM, Howard Pritchard wrote:
Hi Folks,

I"m trying to run the mpi_test_suite test from ompi-tests.  I'm noticing
that if I try to run the io tests, I get an error in the read_all_begin
test:

STATIC READ ALL BEGIN

STATIC READ ALL END

(io/tst_file_read_all_begin.c:82) ERROR: Error in position; Invalid
argument(22)(io/tst_file_read_all_begin.c:82) ERROR: Error in position;
Invalid argument(22)(io/tst_file_read_all_begin.c:82) ERROR: Error in
position; Invalid argument(22)(io/tst_file_read_all_begin.c:82) ERROR:
Error in position; Invalid argument(22)

-------------------------------------------------------

Are there known issues with the io tests?  My first guess is yes
since I notice esslingen is excluding io from their MTT runs.

Thanks for any info,

Howard



_______________________________________________
devel mailing list
[email protected]
Subscription: http://www.open-mpi.org/mailman/listinfo.cgi/devel
Link to this post: 
http://www.open-mpi.org/community/lists/devel/2015/03/17116.php


--
Edgar Gabriel
Associate Professor
Parallel Software Technologies Lab      http://pstl.cs.uh.edu
Department of Computer Science          University of Houston
Philip G. Hoffman Hall, Room 524        Houston, TX-77204, USA
Tel: +1 (713) 743-3857                  Fax: +1 (713) 743-3335

Reply via email to