> I was wondering what set up people find works best.  I note in the setup 
> instructions at https://github.com/cozybit/open80211s/wiki/HOWTO it talks 
> about bridging the mesh interface and the external port.  Does this satisfy 
> everyone's architecture ?
>
Bridging creates a L2 architecture. You need to turn on STP for each
MPP. Henning did point out that we did not clear the mpp table. So if
the number of MAC addresses grow too "big", may cause memory leak.
With L2, the IP addresses for all are same and easy for roaming
purpose.

> Would it be possible (advantageous -- detrimental ?) to do this with routing 
> ??
Depends on your need.

> What other setups have people used ??
For o11s mesh, bridging is my preference cause it allows us to have
MAC routing or MAC path selecting.

----
Chun-Yeow
_______________________________________________
Devel mailing list
[email protected]
http://lists.open80211s.org/cgi-bin/mailman/listinfo/devel