Hello,

On 2.11.22 4:32, Kui Liu wrote:

[snip]

[LIU]:  QUEUE_FLAG_STANDBY bit MUST be cleared here, as it is the only place 
where
the ploop device recovers from standby mode.  In our use case, once a ploop 
device enters standby
  mode, the userspace will initiate recovery by replacing the top delta file 
without destroying
the device, which is why the bit is clear in 'repalce_delta' in vz7.

static int ploop_replace_delta(struct ploop_device * plo, unsigned long arg)
{
...
        if (plo->maintenance_type != PLOOP_MNTN_OFF)
                return -EBUSY;
...
}

If that is used to clear the flag then how is the case when the error occurs while in maintenace handled? I think we should address this too.


--
Regards,
Alexander Atanasov