On 15/04/2020 14:02, Utkarsh Rai wrote:
> + status = clock_gettime( CLOCK_MONOTONIC, &end_time );
> + rtems_test_assert( status == 0 );
> +
> + rtems_test_assert( (end_time.tv_sec-init_time.tv_sec) == 0 );
Is end_time.tv_sec - init_time.tv_sec == 0 under all circumstances?
My idea was to check for a 1ns delay with a reasonable amount of
overhead, hence I checked for end_time.tv_sec - init_time.tv_sec == 0.
Exists there a value of init_time for which end_time.tv_sec !=
init_time.tv_sec and still 1ns elapsed?