On 20/6/20 7:12 am, Joel Sherrill wrote: > *** Is there a reliable way to know the stack is settled out before the > application can run?
This is a hard one. Some interfaces have PHYs that take different times to come up, is the stack ready when one of several interfaces is available? Then there is DHCP and the speed of the server responding. I see the state of networking as a system level specification and it is the system design that needs to take this into consideration. Chris _______________________________________________ devel mailing list devel@rtems.org http://lists.rtems.org/mailman/listinfo/devel