On 20/6/20 7:12 am, Joel Sherrill wrote:
> *** Is there a reliable way to know the stack is settled out before the
> application can run?

This is a hard one. Some interfaces have PHYs that take different times to come
up, is the stack ready when one of several interfaces is available? Then there
is DHCP and the speed of the server responding.

I see the state of networking as a system level specification and it is the
system design that needs to take this into consideration.

Chris