Hi,
We have a report that uses a temporary table.
When we run the report, it crashes with the following error:

"A system error has occurred, preventing the navision axapta client
from continuing."

The Axapta session closes and a dump file is generated (see below).
I synchonised the temporary table and the problem was rectified for
everyone EXCEPT 3 TIER FAT CLIENTS!! We've refreshed caches (usage
data & *aoc files), restarted AOSs, synchronised DB. Still, for only
a 3 tier fat client, the report crashes with this error and dump
file.

Could someone outline some steps/tests that I could perform on site ?
Rgds
tom lalor

Axapta Crash Dump File for Axapta build 1951.2410 (Aug 19 2003
19:44:15)
Dumped  : Wed Sep 08 11:31:22 2004

Crash   : Exception 0xc0000005 caught (unspecified) in thread 0x62c
of process 0x4e4.
-------------------------------------------------------------

--# FV EIP----- RetAddr- FramePtr StackPtr Symbol

  0 .V 0052a385 0000008f 02c40034 0012d4cc     Mod:  ax32[ax32.exe],
base: 00400000h

Stackdump exit code 487 (Attempt to access invalid address)





Yahoo! Groups Sponsor
ADVERTISEMENT
click here


Yahoo! Groups Links