Best Regards.
Anson huang 黄勇才
 
Freescale Semiconductor Shanghai
上海浦东新区亮景路192号A座2楼
201203
Tel:021-28937058


>-----Original Message-----
>From: Shawn Guo [mailto:[email protected]]
>Sent: Thursday, December 19, 2013 5:11 PM
>To: Huang Yongcai-B20788
>Cc: [email protected]; [email protected]; [email protected];
>[email protected]; [email protected]; linux-arm-
>[email protected]; [email protected]
>Subject: Re: [PATCH V2 2/2] thermal: imx: add necessary clk operation
>
>On Thu, Dec 19, 2013 at 03:53:22PM -0500, Anson Huang wrote:
>> Thermal sensor needs pll3_usb_otg when measuring temperature,
>> otherwise the temperature read will be incorrect, so need to enable
>> this clk before sensor working, for alarm function, as hardware will
>> take measurement periodically, so we should keep this clk always on
>> once alarm function is enabled.
>>
>> Signed-off-by: Anson Huang <[email protected]>
>> ---
>>  .../devicetree/bindings/thermal/imx-thermal.txt    |    2 ++
>>  drivers/thermal/imx_thermal.c                      |   18
>++++++++++++++++++
>>  2 files changed, 20 insertions(+)
>>
>> diff --git a/Documentation/devicetree/bindings/thermal/imx-thermal.txt
>> b/Documentation/devicetree/bindings/thermal/imx-thermal.txt
>> index 541c25e..e518c6e 100644
>> --- a/Documentation/devicetree/bindings/thermal/imx-thermal.txt
>> +++ b/Documentation/devicetree/bindings/thermal/imx-thermal.txt
>> @@ -7,6 +7,7 @@ Required properties:
>>  - fsl,tempmon-data : phandle pointer to fuse controller that contains
>TEMPMON
>>    calibration data, e.g. OCOTP on imx6q.  The details about calibration
>data
>>    can be found in SoC Reference Manual.
>> +- clocks : thermal sensor's clock source.
>
>This should be listed in 'Optional properties:' now.

Right, will send a V3 later.
 

>
>Shawn
>
>>
>>  Example:
>>
>> @@ -14,4 +15,5 @@ tempmon {
>>      compatible = "fsl,imx6q-tempmon";
>>      fsl,tempmon = <&anatop>;
>>      fsl,tempmon-data = <&ocotp>;
>> +    clocks = <&clks 172>;
>>  };
>> diff --git a/drivers/thermal/imx_thermal.c
>> b/drivers/thermal/imx_thermal.c index 1d6c801..c2b8173 100644
>> --- a/drivers/thermal/imx_thermal.c
>> +++ b/drivers/thermal/imx_thermal.c
>> @@ -7,6 +7,7 @@
>>   *
>>   */
>>
>> +#include <linux/clk.h>
>>  #include <linux/cpu_cooling.h>
>>  #include <linux/cpufreq.h>
>>  #include <linux/delay.h>
>> @@ -73,6 +74,7 @@ struct imx_thermal_data {
>>      unsigned long last_temp;
>>      bool irq_enabled;
>>      int irq;
>> +    struct clk *thermal_clk;
>>  };
>>
>>  static void imx_set_alarm_temp(struct imx_thermal_data *data, @@
>> -457,6 +459,22 @@ static int imx_thermal_probe(struct platform_device *pdev)
>>              return ret;
>>      }
>>
>> +    data->thermal_clk = devm_clk_get(&pdev->dev, NULL);
>> +    if (IS_ERR(data->thermal_clk)) {
>> +            dev_warn(&pdev->dev, "failed to get thermal clk!\n");
>> +    } else {
>> +            /*
>> +             * Thermal sensor needs clk on to get correct value, normally
>> +             * we should enable its clk before taking measurement and 
>> disable
>> +             * clk after measurement is done, but if alarm function is 
>> enabled,
>> +             * hardware will auto measure the temperature periodically, so 
>> we
>> +             * need to keep the clk always on for alarm function.
>> +             */
>> +            ret = clk_prepare_enable(data->thermal_clk);
>> +            if (ret)
>> +                    dev_warn(&pdev->dev, "failed to enable thermal clk: 
>> %d\n",
>ret);
>> +    }
>> +
>>      /* Enable measurements at ~ 10 Hz */
>>      regmap_write(map, TEMPSENSE1 + REG_CLR, TEMPSENSE1_MEASURE_FREQ);
>>      measure_freq = DIV_ROUND_UP(32768, 10); /* 10 Hz */
>> --
>> 1.7.9.5
>>
>>