On Mon, Jan 05, 2015 at 08:30:05AM -0500, Tejun Heo wrote:
> On Mon, Jan 05, 2015 at 03:51:45PM +0530, Suman Tripathi wrote:
> > Due to H/W errata, the controller is unable to save the PMP
> > field fetched from command header before sending the H2D FIS.
> > When the device returns the PMP port field in the D2H FIS, there is
> > a mismatch and results in command completion failure. The workaround
> > is to write the pmp value to PxFBS.DEV field before issuing any command
> > to PMP.
> > 
> > Signed-off-by: Suman Tripathi <[email protected]>
> 
> Applied 1-2 to libata/for-3.20.

Reverted due to conflicts with the endian fix patches.  Please rebase
these two on top of them.

Thanks.

-- 
tejun
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to