<b>Trillian test result (tid-2955)</b> Environment: kvm-centos7 (x2), Advanced Networking with Mgmt server 7 Total time taken: 61381 seconds Marvin logs: https://github.com/blueorangutan/acs-prs/releases/download/trillian/pr2816-t2955-kvm-centos7.zip Intermitten failure detected: /marvin/tests/smoke/test_accounts.py Intermitten failure detected: /marvin/tests/smoke/test_certauthority_root.py Intermitten failure detected: /marvin/tests/smoke/test_deploy_virtio_scsi_vm.py Intermitten failure detected: /marvin/tests/smoke/test_deploy_vm_iso.py Intermitten failure detected: /marvin/tests/smoke/test_internal_lb.py Intermitten failure detected: /marvin/tests/smoke/test_privategw_acl.py Intermitten failure detected: /marvin/tests/smoke/test_public_ip_range.py Intermitten failure detected: /marvin/tests/smoke/test_router_dhcphosts.py Intermitten failure detected: /marvin/tests/smoke/test_templates.py Intermitten failure detected: /marvin/tests/smoke/test_usage.py Intermitten failure detected: /marvin/tests/smoke/test_vm_life_cycle.py Intermitten failure detected: /marvin/tests/smoke/test_volumes.py Intermitten failure detected: /marvin/tests/smoke/test_vpc_redundant.py Intermitten failure detected: /marvin/tests/smoke/test_host_maintenance.py Intermitten failure detected: /marvin/tests/smoke/test_hostha_kvm.py Smoke tests completed. 58 look OK, 11 have error(s) Only failed tests results shown below:
Test | Result | Time (s) | Test File --- | --- | --- | --- ContextSuite context=TestTemplateHierarchy>:setup | `Error` | 1585.73 | test_accounts.py ContextSuite context=TestDeployVirtioSCSIVM>:setup | `Error` | 0.00 | test_deploy_virtio_scsi_vm.py test_deploy_vm_from_iso | `Error` | 1563.80 | test_deploy_vm_iso.py test_03_vpc_privategw_restart_vpc_cleanup | `Failure` | 235.19 | test_privategw_acl.py test_04_extract_template | `Failure` | 128.38 | test_templates.py ContextSuite context=TestISOUsage>:setup | `Error` | 0.00 | test_usage.py test_02_unsecure_vm_migration | `Error` | 87.04 | test_vm_life_cycle.py test_06_download_detached_volume | `Failure` | 137.61 | test_volumes.py test_04_rvpc_network_garbage_collector_nics | `Failure` | 521.05 | test_vpc_redundant.py test_02_cancel_host_maintenace_with_migration_jobs | `Error` | 3.38 | test_host_maintenance.py test_hostha_enable_ha_when_host_in_maintenance | `Error` | 2.67 | test_hostha_kvm.py [ Full content available at: https://github.com/apache/cloudstack/pull/2816 ] This message was relayed via gitbox.apache.org for [email protected]