https://issues.dlang.org/show_bug.cgi?id=21101
Walter Bright <[email protected]> changed: What |Removed |Added ---------------------------------------------------------------------------- Status|NEW |RESOLVED Resolution|--- |INVALID --- Comment #1 from Walter Bright <[email protected]> --- The problem is, being assembler code, there is no distinction between signed and unsigned values for immediate values. The instruction semantics determine if it is signed or unsigned. The values are all computed as 64 bit integers. Hence, -2 is indistinguishable from 0xFFFFFFFFFFFFFFFE. Whether it gets truncated or sign extended is determined by the instruction, there is no concept of a signed or unsigned immediate value. It's working as designed. --