Hi Travist, "clock skew too great" are usually related to the clock on the client and the AD server being too far apart (5mins if I remember correctly). Time being synced is fairly critical with these kinds of setup.
If EON is being synced from this same AD server, the only thing I can say is to make sure both servers are using the same timezone (eg PST8PDT for both). You can also check the drift file for the difference. Other than that it seems something else is causing the time to be off or drifting apart. see the command set to help trouble shoot and correspond the values of time http://sites.google.com/site/eonstorage/faq#TOC-How-do-I-check-internet-time-sync- -- This message posted from opensolaris.org _______________________________________________ distribution-discuss mailing list [email protected] http://mail.opensolaris.org/mailman/listinfo/distribution-discuss