Hi Jukka,
At 03:21 17-01-2008, Jukka Salmi wrote:
>Yesterday I saw the problem again, but the order of events was slightly
>different:
>
>- A remote MTA (sf.net) connects to my MTA (mx1).
>
>- The same remote MTA (sf.net) opens a second connection to mx1 and
>   tries to deliver a message with the same message id as in the first
>   (still open) connection.

That shouldn't be a problem as the message-id is considered as a just 
a string by the milter.


>- After 5 minutes (which is my Postfix milter_content_timeout setting)
>   both connections are rejected:
>
>     postfix/cleanup[6973]: warning: milter inet:localhost:1026:
>       can't read SMFIC_BODYEOB reply packet header:
>       Operation timed out

Would

>     postfix/cleanup[6973]: CDE4C24C7D: milter-reject:
>       END-OF-MESSAGE from [...]: 4.7.1 Service unavailable - [...]
>
>- Some minutes later another remote MTA (cloud9.net) connects to mx1.
>   The message is rejected imediately:
>
>     postfix/cleanup[14447]: warning: milter inet:localhost:1026:
>       can't read SMFIC_BODYEOB reply packet header: Undefined error: 0

Can you enable logging of milter events?

Regards,
-sm 


-------------------------------------------------------------------------