Options only valid for HSG80 and MSA/HSV 1x0 arrays with Active/Standby mode
exclusively, their firmware can not be upgraded to support ALUA.

Cc: Christophe Varoqui <[email protected]>
Cc: device-mapper development <[email protected]>
Signed-off-by: Xose Vazquez Perez <[email protected]>
---
 multipath/multipath.conf.5 | 11 ++++++-----
 1 file changed, 6 insertions(+), 5 deletions(-)

diff --git a/multipath/multipath.conf.5 b/multipath/multipath.conf.5
index a59e7a1..e7df08c 100644
--- a/multipath/multipath.conf.5
+++ b/multipath/multipath.conf.5
@@ -228,8 +228,8 @@ Generate the path priority for LSI/Engenio/NetApp RDAC 
class as NetApp E/EF
 Series, and OEM arrays from IBM DELL SGI STK and SUN.
 .TP
 .I hp_sw
-Generate the path priority for Compaq/HP controller in
-active/standby mode.
+Generate the path priority for HP/COMPAQ/DEC HSG80 and MSA/HSV arrays with
+Active/Standby mode exclusively.
 .TP
 .I hds
 Generate the path priority for Hitachi HDS Modular storage arrays.
@@ -311,7 +311,8 @@ Query the DGC/EMC specific EVPD page 0xC0 to determine the 
path state
 for CLARiiON CX/AX and EMC VNX arrays families.
 .TP
 .I hp_sw
-Check the path state for HP storage arrays with Active/Standby firmware.
+Check the path state for HP/COMPAQ/DEC HSG80 and MSA/HSV arrays with
+Active/Standby mode exclusively.
 .TP
 .I rdac
 Check the path state for LSI/Engenio/NetApp RDAC class as NetApp E/EF
@@ -818,8 +819,8 @@ Hardware handler for LSI/Engenio/NetApp RDAC class as 
NetApp E/EF
 Series, and OEM arrays from IBM DELL SGI STK and SUN.
 .TP
 .I 1 hp_sw
-Hardware handler for Compaq/HP storage arrays in active/standby
-mode.
+Hardware handler for HP/COMPAQ/DEC HSG80 and MSA/HSV arrays with
+Active/Standby mode exclusively.
 .TP
 .I 1 alua
 Hardware handler for SCSI-3 ALUA compatible arrays.
-- 