On Tue, Mar 25, 2008 at 09:26:13AM +0100, Kristen Kaasbjerg wrote: > Johan Jansson wrote: > > [EMAIL PROTECTED] wrote: > >>> Yes, the mesh ordering used in DOLFIN (intentionally) screws up any > >>> ordering, like all cells being "right-oriented" or similar. > >>> > >>> If this is a problem for GTS, we need to do something about the GTS > >>> interface (not the mesh). > >>> > >>> > >> > >> hhmm, ok. > >> Does this reordering mean that the cell numbers before and after > >> differ ? > >> If not, then I'll just do the cell searching before it is reordered and > >> then pass the cell number to the eval function as well. > >> > >> Kristen > >> > > > > I've implemented the local re-ordering for tetrahedra, could you give > > it a try again? > > > > Johan > > > Perfect, seems to work now. I get some very annoying output printing > though. Every time I call eval, the following information is printed: > d1: 0.0411 > d2: 0.0153 > d3: 0.0553 > d4: -0.01 > > Kristen
Fixed. -- Anders _______________________________________________ DOLFIN-dev mailing list [email protected] http://www.fenics.org/mailman/listinfo/dolfin-dev