I understand now. Carlos, in that case, go with 221V and be happy. 
Check the tube filament voltages, just to be sure.  If less than or
equal to 5 VAC, all is well.

regards,

Mahlon - K4OQ

PY 1 HA wrote:
> 
>  Hi all
> The power supply in Brazil can be 127/220v or 220/380v depending the region
> (except in some rural areas that is 115/230v one phase)
> It is 3 phase and neutral ,for ex, 220v between each phase and 127v between
> any phase and neutral (220v/1.73=127v) (1.73 square root of 3)
> george
>
----------------------------------------------------------------------
Submissions:        [EMAIL PROTECTED]
Subscribe:          [EMAIL PROTECTED] - subscribe drakelist in body
Unsubscribe:        [EMAIL PROTECTED] - unsubscribe drakelist in body
Hopelessly Lost:    [EMAIL PROTECTED] - help in body of message
Brought to you courtesy of TLCHost.net  http://www.tlchost.net
----------------------------------------------------------------------