"Rasmus Weijola" <[EMAIL PROTECTED]> made an utterance to the drakelist gang ---------------------------------------------------------------------- Scheduled 3 conversions from AC-4 to AC-4R
First one worked instantly, no problem. Second one which hasn“t worked with TR-4 any didnt do it after the conversion either. The 300 V supply drops to 200 V with TR4 any but stays by 270 with T4XC. I disconnected the yellow cable and loaded with different resistors and somehow this PS cant supply an TR-4. Any logical explanations ? Must be the transformer ? How ? Rasmus OH6KH ---------------------------------------------------------------------- Submissions: [email protected] Unsubscribe: [EMAIL PROTECTED] - unsubscribe drakelist in body Hopelessly Lost: [EMAIL PROTECTED] - help in body of message Zerobeat Web Page: www.zerobeat.net - sponsored by www.tlchost.net ----------------------------------------------------------------------