On Wed, 10 Nov 2010 13:15:06 -0500, Garey Barrell wrote: >Certainly seems that in your case you just >had some crumbly solder. Only took 50 years for it to show up!! :-)
I found a cracked solder joint in a TR-7 PTO not long ago, using a method similar to Eddy's. The connection appeared entirely normal, except that the cut end of the wire poking through the solder seemed to be bent at an odd angle. The symptom was intermittent PTO operation, and the cause finally presented itself when the solder joint in question was 'stimulated' with a non-conductive tool. Orange wood sticks work well for such probing, they are soft enough that you're not going to hurt anything. 73 -Jim -- Ham Radio NU0C Lincoln, Nebraska, U.S.S.A. TR7/RV7/R7A/L7, TR6/RV6, T4XC/R4C/L4B, NCL2000, SB104A, R390A, GT550A/RV550A, HyGain 3750, IBM PS/2 - all vintage, all the time! "Give a man a URL, and he will learn for an hour; teach him to Google, and he will learn for a lifetime." HyGain 3750 User's Group - http://groups.yahoo.com/group/HyGain_3750/ http://radiojim.exofire.net http://incolor.inetnebr.com/jshorney http://www.nebraskaghosts.org _______________________________________________ Drakelist mailing list [email protected] http://mailman.zerobeat.net/mailman/listinfo/drakelist