Sheldon,

That means the PLL is out of lock.  The most common cause is mild corrosion
on the card contacts.  Re-seating the cards will usually fix that problem
plus a few problems you haven't yet discovered.

Take care not to bump the pots on the right front.

Tom, AG9X



On Sun, May 19, 2013 at 11:05 AM, Sheldon Gofberg <[email protected]>wrote:

>
> I've just acquired a TR7 that has full output and is functional on all
> bands except ten and fifteen meters.  On those bands, the displayed
> frequency starts at 51.xxxxxx and continues to count up.
> Not sure what's going on.  Anyone familiar with this condition?
> Thank you.  K3PNI. Sheldon
> Sent from my iPad
> _______________________________________________
> Drakelist mailing list
> [email protected]
> http://mailman.zerobeat.net/mailman/listinfo/drakelist
>