On Mon, Dec 17, 2012 at 3:09 PM, Caspar Smit <[email protected]> wrote: > Hi Rasto, > > I noticed this in one of my clusters: > ...
> /usr/local/bin/lcmc-gui-helper-1.4.2 hw-info-daemon > root 9869 0.0 0.0 39856 1516 pts/7 S+ 14:49 0:00 > \_ sudo -E -p DRBD MC sudo pwd: /usr/local/bin/lcmc-gui-helper-1.4.2 > hw-info-daemon > root 9870 0.3 0.0 27676 5000 pts/7 S+ 14:49 0:00 > \_ /usr/bin/perl /usr/local/bin/lcmc-gui-helper-1.4.2 hw-info-daemon > root 18176 0.0 0.0 9060 1180 pts/7 S+ 14:50 0:00 > \_ sh -c /sbin/pvdisplay -C --noheadings -o pv_name,vg_name 2>/dev/null > root 18177 0.0 0.0 17872 1604 pts/7 D+ 14:50 0:00 > \_ /sbin/pvdisplay -C --noheadings -o pv_name,vg_name > > Why is LCMC running so many pvdisplay commands at once? Hi Caspar, it is running it once in 10 seconds, to see if something has changed. Can you check what does it do on your nodes? /sbin/pvdisplay -C --noheadings -o pv_name,vg_name Rasto > > I think this is causing my RA monitors to timeout once in a while (sometimes > even two minutes timeout) > > Kind regards, > Caspar Smit > -- Dipl.-Ing. Rastislav Levrinc [email protected] Linux Cluster Management Console http://lcmc.sf.net/ _______________________________________________ drbd-mc mailing list [email protected] http://lists.linbit.com/mailman/listinfo/drbd-mc