On Thu, Jan 19, 2012 at 11:52:03AM +0000, Oren Nechushtan wrote:
> 
> 
> 
> 
> Hi everyone,
> First, I would like to express my pleasure using DRBD!
> Here is my situation:
>  
> Two-node setup, using cman and pacemaker, don't care about quorum, no 
> stonithMaster-Slave DRBD resource
> Fence resource only
> I noticed that under certain settings (powering on/off nodes enough times) 
> the secondary node may never becomes promoted when primary is shutdown. 

I *think* that is intentional, and preventing potential data divergence,
in the following scenario:

 * all good, Primary --- connected --- Secondary
 * Kill Secondary, Primary continues.
 * Powerdown Primary.
 * Bring up Secondary only.

What use is fencing, if a fencing loop would cause data divergence anyways.

> Here is a sample log (attached)
>  
> Jan 18 08:34:52 NODE-1 crmd: [2054]: info: do_lrm_rsc_op: Performing 
> key=7:89911:0:aac20e27-939f-439c-b461-e668262718b3 op=drbd_fsroot:0_promote_0 
> )
> Jan 18 08:34:52 NODE-1 lrmd: [2051]: info: rsc:drbd_fsroot:0:299768: promote
> Jan 18 08:34:52 NODE-1 kernel: block drbd0: helper command: /sbin/drbdadm 
> fence-peer minor-0
> Jan 18 08:34:52 NODE-1 corosync[1759]:   [TOTEM ] Automatically recovered 
> ring 1
> Jan 18 08:34:53 NODE-1 crm-fence-peer.sh[24325]: invoked for fsroot
> Jan 18 08:34:53 NODE-1 corosync[1759]:   [TOTEM ] Automatically recovered 
> ring 1

> Jan 18 08:34:53 NODE-1 crm-fence-peer.sh[24325]: WARNING peer is unreachable, 
> my disk is Consistent: did not place the constraint!

This is it.

-- 
: Lars Ellenberg
: LINBIT | Your Way to High Availability
: DRBD/HA support and consulting http://www.linbit.com
_______________________________________________
drbd-user mailing list
[email protected]
http://lists.linbit.com/mailman/listinfo/drbd-user