Hello, On 02/21/2012 05:17 PM, venkatesh prabhu wrote: > Hi, > I am facing issue in degraded timeout. > My two node cluster with DRBD is up and running. > But the degr-wfc-timeout is not working as expected. > > I have primary and secondary node. > Then i shutdown the secondary node, then making some changes in mirror > from the primary node and rebooting. > When it comes up it is waiting for 180 seconds instead of 3 seconds. > <See the config section provided below> > Please let me know what could be the problem.
It is working as expected: degr-wfc-timeout would be triggered if the Primary crashes while running in a degraded cluster ... on regular shutdown and reboot afterwards wfc-timeout is used. Reset your single Primary and you should see degr-wfc-timeout being triggered. Regards, Andreas -- Need help with DRBD? http://www.hastexo.com/now > My confgi section for timeouts; > startup { > degr-wfc-timeout 3; #3 sec.. > > wfc-timeout 180; # 3 min. > > # become-primary-on both; > } # end of startup > > -- > Thanks in Advance. > > Vengatesh Prabhu > Life is Beautiful: > _______________________________________________ > drbd-user mailing list > [email protected] > http://lists.linbit.com/mailman/listinfo/drbd-user
signature.asc
Description: OpenPGP digital signature
_______________________________________________ drbd-user mailing list [email protected] http://lists.linbit.com/mailman/listinfo/drbd-user