----- Original Message -----
> From: "pierpaolo.fasano" <[email protected]>
> To: [email protected]
> Sent: Friday, March 16, 2012 8:32:03 AM
> Subject: [DRBD-user] Switch from MD to DRBD
> 
> Hi,
> I'm in the middle of switching from a software RAID1 based on MD to
> another one based on DRBD but using the same disks.
> I've verified that no data loss occurs during this operation, but I'm
> wondering if it's possible to avoid the initial full synchronization
> between disks since I'm sure the two disks are already mirrored by
> MD.
> Is it possible to achieve it and in which way?

Not sure this is the right answer without further information about your setup 
- what you have and where you're headed (you have 2 disk MD RAID 1... and are 
moving one of the disks to a new server? going to have DRBD on top of MD?) 
but...

You should be able to add the the meta data to the existing array with 
something similiar to this:
http://lists.linbit.com/pipermail/drbd-user/2009-February/011464.html

Then removed the mirror drive and do a "truck-based" replication explained here 
- specifically appropriate case listed under #2:
http://www.drbd.org/users-guide-legacy/s-using-truck-based-replication.html

HTH

Jake
_______________________________________________
drbd-user mailing list
[email protected]
http://lists.linbit.com/mailman/listinfo/drbd-user