On 12/05/15 03:42 AM, DRBD User wrote:
>>>> pacemakers pcs property stonith-enabled is currently set to false
> 
>> Well there's your problem. :)
> 
> Since i don't have any (hardware) STONITH device, i have set stonith-enabled 
> to false.
> DRBD's fencing rule is set to : 'fencing: resource-only'
> 
> My goal is: if one node crashes, the other node should take over the work 
> immediately. But actually i have to wait the reboot time of the crashed node. 
> I thought, that in such a situation the active node (rather the shared 
> directory) is immediately usable ?
> 
> May be i should use another fence script ?
> 
> I tried to create the resource with operation 'on-fail=restart' - but no 
> success ...
> 
> Any other suggestions ?

You *CAN NOT* safely proceed when a node stops responding _until_ you
have put the lost node into a known state. To do otherwise would be to
risk a split-brain.

A good fence device are switched PDUs, like the APC-brand AP7900 (not
all makes/models are supported, so check first before buying other
brands). The AP7900 can usually be found used for ~$200 and makes an
excellent external fence device.

Trying to use DRBD without proper fencing will result in pain and
heartache. The delay needed to fence a lost node is FAR preferable to
risking a split-brain.

-- 
Digimer