Mika,

Can you take a look at this?

-DK

On Fri, 2016-11-04 at 14:06 -0700, Dhinakaran Pandiyan wrote:
> The DP device identification string read from the DPCD registers is 6
> characters long at max. and we store it in a char array of the same length
> without space for the NULL terminator. Fix this by increasing the array
> size to 7 and initialize it to an empty string.
> 
> Signed-off-by: Dhinakaran Pandiyan <dhinakaran.pandiyan at intel.com>
> ---
>  drivers/gpu/drm/drm_dp_helper.c | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
> 
> diff --git a/drivers/gpu/drm/drm_dp_helper.c b/drivers/gpu/drm/drm_dp_helper.c
> index 3e6fe82..3a39312 100644
> --- a/drivers/gpu/drm/drm_dp_helper.c
> +++ b/drivers/gpu/drm/drm_dp_helper.c
> @@ -544,7 +544,7 @@ void drm_dp_downstream_debug(struct seq_file *m,
>                                DP_DETAILED_CAP_INFO_AVAILABLE;
>       int clk;
>       int bpc;
> -     char id[6];
> +     char id[7] = "";
>       int len;
>       uint8_t rev[2];
>       int type = port_cap[0] & DP_DS_PORT_TYPE_MASK;