Am Montag, 5. März 2018, 09:57:39 CET schrieb Marek Szyprowski:
> From: zain wang <[email protected]>
> 
> The bridge does not need to be powered in analogix_dp_bind(), so
> remove the calls to pm_runtime_get()/phy_power_on()/analogix_dp_init_dp()
> as well as their power-off counterparts.
> 
> Cc: Stéphane Marchesin <[email protected]>
> Signed-off-by: zain wang <[email protected]>
> Signed-off-by: Caesar Wang <[email protected]>
> [the patch originally just removed the power_on portion, seanpaul removed
> the power off code as well as improved the commit message]
> Signed-off-by: Sean Paul <[email protected]>
> Signed-off-by: Thierry Escande <[email protected]>
> Signed-off-by: Marek Szyprowski <[email protected]>

on top of current drm-misc-next on rk3288 and rk3399
Tested-by: Heiko Stuebner <[email protected]>

and the actual change also looks sane of course, so
Reviewed-by: Heiko Stuebner <[email protected]>
_______________________________________________
dri-devel mailing list
[email protected]
https://lists.freedesktop.org/mailman/listinfo/dri-devel

Reply via email to