https://bugzilla.kernel.org/show_bug.cgi?id=205393

--- Comment #9 from har...@gmx.de ---
(In reply to tempel.julian from comment #7)
> Is this really only relevant for Vega 10?
> Also on Polaris voltage is reset to default when using a customized
> powerplay table e.g. after a modeline switch (happens when closing Sway
> session with ctr + shift + e).

I don't have a polaris card for debugging, but looking at the code, i think
that a similar bug could be relevant too. Vega10 is smu9, while Polaris is
smu7, but both firmwares generally support AVFS and enabling/disabling this
feature.

-- 
You are receiving this mail because:
You are watching the assignee of the bug.
_______________________________________________
dri-devel mailing list
dri-devel@lists.freedesktop.org
https://lists.freedesktop.org/mailman/listinfo/dri-devel

Reply via email to