The function dpu_encoder_get_wb() returns controller_id if the
corresponding WB is present in the catalog. We can inline this function
and rely on dpu_rm_get_wb() returning NULL for indices for which the
WB is not present on the device.

Signed-off-by: Dmitry Baryshkov <dmitry.barysh...@linaro.org>
---
 drivers/gpu/drm/msm/disp/dpu1/dpu_encoder.c | 24 ++-------------------
 1 file changed, 2 insertions(+), 22 deletions(-)

diff --git a/drivers/gpu/drm/msm/disp/dpu1/dpu_encoder.c 
b/drivers/gpu/drm/msm/disp/dpu1/dpu_encoder.c
index 4c85cbb030e4..507ff3f88c67 100644
--- a/drivers/gpu/drm/msm/disp/dpu1/dpu_encoder.c
+++ b/drivers/gpu/drm/msm/disp/dpu1/dpu_encoder.c
@@ -1277,22 +1277,6 @@ static enum dpu_intf dpu_encoder_get_intf(const struct 
dpu_mdss_cfg *catalog,
        return INTF_MAX;
 }
 
-static enum dpu_wb dpu_encoder_get_wb(const struct dpu_mdss_cfg *catalog,
-               enum dpu_intf_type type, u32 controller_id)
-{
-       int i = 0;
-
-       if (type != INTF_WB)
-               return WB_MAX;
-
-       for (i = 0; i < catalog->wb_count; i++) {
-               if (catalog->wb[i].id == controller_id)
-                       return catalog->wb[i].id;
-       }
-
-       return WB_MAX;
-}
-
 void dpu_encoder_vblank_callback(struct drm_encoder *drm_enc,
                struct dpu_encoder_phys *phy_enc)
 {
@@ -2261,7 +2245,6 @@ static int dpu_encoder_setup_display(struct 
dpu_encoder_virt *dpu_enc,
                 */
                u32 controller_id = disp_info->h_tile_instance[i];
                enum dpu_intf intf_idx;
-               enum dpu_wb wb_idx;
 
                if (disp_info->num_of_h_tiles > 1) {
                        if (i == 0)
@@ -2279,14 +2262,11 @@ static int dpu_encoder_setup_display(struct 
dpu_encoder_virt *dpu_enc,
                                                            
disp_info->intf_type,
                                                            controller_id);
 
-               wb_idx = dpu_encoder_get_wb(dpu_kms->catalog,
-                               disp_info->intf_type, controller_id);
-
                if (intf_idx >= INTF_0 && intf_idx < INTF_MAX)
                        phys_params.hw_intf = dpu_rm_get_intf(&dpu_kms->rm, 
intf_idx);
 
-               if (wb_idx >= WB_0 && wb_idx < WB_MAX)
-                       phys_params.hw_wb = dpu_rm_get_wb(&dpu_kms->rm, wb_idx);
+               if (disp_info->intf_type == INTF_WB && controller_id < WB_MAX)
+                       phys_params.hw_wb = dpu_rm_get_wb(&dpu_kms->rm, 
controller_id);
 
                if (!phys_params.hw_intf && !phys_params.hw_wb) {
                        DPU_ERROR_ENC(dpu_enc, "no intf or wb block assigned at 
idx: %d\n", i);
-- 
2.39.2

Reply via email to