In order to move the panel/bridge parsing and attachmenet to the
Analogix side, add component struct drm_bridge *next_bridge to
platform data struct analogix_dp_plat_data.

The movement makes sense because the panel/bridge should logically
be positioned behind the Analogix bridge in the display pipeline.

Signed-off-by: Damon Ding <damon.d...@rock-chips.com>
Reviewed-by: Dmitry Baryshkov <dmitry.barysh...@oss.qualcomm.com>

---

Changes in v4:
- Rename the &analogix_dp_plat_data.bridge to
  &analogix_dp_plat_data.next_bridge
---
 include/drm/bridge/analogix_dp.h | 1 +
 1 file changed, 1 insertion(+)

diff --git a/include/drm/bridge/analogix_dp.h b/include/drm/bridge/analogix_dp.h
index cf17646c1310..582357c20640 100644
--- a/include/drm/bridge/analogix_dp.h
+++ b/include/drm/bridge/analogix_dp.h
@@ -27,6 +27,7 @@ static inline bool is_rockchip(enum analogix_dp_devtype type)
 struct analogix_dp_plat_data {
        enum analogix_dp_devtype dev_type;
        struct drm_panel *panel;
+       struct drm_bridge *next_bridge;
        struct drm_encoder *encoder;
        struct drm_connector *connector;
        bool skip_connector;
-- 
2.34.1