On 27/10/2026 20:04, Paul Cercueil wrote:
>>> +
>>> +  port:
>>> +    $ref: /schemas/graph.yaml#/properties/port
>>> +    description: The output, to the panel or bridge.
>>
>> No port for IPU?
> 
> No IPU on the X1600 - the display IP is completely different there
> (hence the new binding).

But even if it is different, don't you need to represent the datapath?
Your LCD controller does not need IPU?

Best regards,
Krzysztof