On Tue, Mar 23, 2010 at 1:29 PM, opensolaris_user hello <
opensolarisuser2...@gmail.com> wrote:

> Hi,
>
> I am running Opensolaris on a HP Proliant server using the driver from
> Solaris10.
>
> Here's the link about the driver:
>
>
> http://lanestechblog.blogspot.com/2009/02/installing-opensolaris-200811-on-server.html
>
>
> My question is for whatever reason the slot 7 never shows up either in the
> format output or in /etc/path_to_instance file. The disks were configured
> using the HP storage controller as individual disks so that it shows up as
> 'n' separate  disks for Zpool. Is there any way to know why slot 7 is not
> detected.
> The controller detects the slot 7 fine. I saw this behavior on 2 HP boxes
> that we have. The node has 2 boxes of 8 disks each and Opensolaris can
> detect
>  only 15 disks instead of 16.
>
>
> /etc/path_to_instance
> =================
>
> "/p...@0,0/pci8086,3...@1" 0 "pcie_pci"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0" 0 "cpqary3"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@1,0" 1 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@2,0" 2 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@3,0" 3 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@4,0" 4 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@5,0" 5 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@6,0" 6 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@8,0" 8 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@9,0" 9 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@a,0" 10 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@b,0" 11 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@c,0" 12 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@d,0" 13 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@e,0" 14 "sd"
> "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@f,0" 15 "sd"
> "/p...@0,0/pci8086,3...@5" 4 "pcie_pci"
>
> Format
> ======
>
> AVAILABLE DISK SELECTIONS:
>        0. c7t1d0 <DEFAULT cyl 17841 alt 2 hd 255 sec 63>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@1,0
>        1. c7t2d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@2,0
>        2. c7t3d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@3,0
>        3. c7t4d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@4,0
>        4. c7t5d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@5,0
>        5. c7t6d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@6,0
>        6. c7t8d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@8,0
>        7. c7t9d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@9,0
>        8. c7t10d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@a,0
>        9. c7t11d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@b,0
>       10. c7t12d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@c,0
>       11. c7t13d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@d,0
>       12. c7t14d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@e,0
>       13. c7t15d0 <HP-LOGICAL VOLUME-2.50-136.70GB>
>           /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@f,0
>
>
> prtconf
> ======
>
>     pci, instance #0
>         pci103c,330b (driver not attached)
>         pci8086,3408, instance #0
>             pci103c,3245, instance #0
>                 sd, instance #1
>                 sd, instance #2
>                 sd, instance #3
>                 sd, instance #4
>                 sd, instance #5
>                 sd, instance #6
>                 sd, instance #8
>                 sd, instance #9
>                 sd, instance #10
>                 sd, instance #11
>                 sd, instance #12
>                 sd, instance #13
>                 sd, instance #14
>                 sd, instance #15
>         pci8086,3409 (driver not attached)
>
> Any assistance is highly appreciated,
>
> Thanks,
> Satya
>
>
>


ID7 is reserved for the SCSI host bus adapter by default.

http://www.sun.com/blueprints/0800/scsi.pdf

--Tim
_______________________________________________
driver-discuss mailing list
driver-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/driver-discuss

Reply via email to