On Tue, Mar 23, 2010 at 1:29 PM, opensolaris_user hello < opensolarisuser2...@gmail.com> wrote:
> Hi, > > I am running Opensolaris on a HP Proliant server using the driver from > Solaris10. > > Here's the link about the driver: > > > http://lanestechblog.blogspot.com/2009/02/installing-opensolaris-200811-on-server.html > > > My question is for whatever reason the slot 7 never shows up either in the > format output or in /etc/path_to_instance file. The disks were configured > using the HP storage controller as individual disks so that it shows up as > 'n' separate disks for Zpool. Is there any way to know why slot 7 is not > detected. > The controller detects the slot 7 fine. I saw this behavior on 2 HP boxes > that we have. The node has 2 boxes of 8 disks each and Opensolaris can > detect > only 15 disks instead of 16. > > > /etc/path_to_instance > ================= > > "/p...@0,0/pci8086,3...@1" 0 "pcie_pci" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0" 0 "cpqary3" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@1,0" 1 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@2,0" 2 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@3,0" 3 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@4,0" 4 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@5,0" 5 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@6,0" 6 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@8,0" 8 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@9,0" 9 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@a,0" 10 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@b,0" 11 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@c,0" 12 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@d,0" 13 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@e,0" 14 "sd" > "/p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@f,0" 15 "sd" > "/p...@0,0/pci8086,3...@5" 4 "pcie_pci" > > Format > ====== > > AVAILABLE DISK SELECTIONS: > 0. c7t1d0 <DEFAULT cyl 17841 alt 2 hd 255 sec 63> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@1,0 > 1. c7t2d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@2,0 > 2. c7t3d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@3,0 > 3. c7t4d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@4,0 > 4. c7t5d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@5,0 > 5. c7t6d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@6,0 > 6. c7t8d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@8,0 > 7. c7t9d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@9,0 > 8. c7t10d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@a,0 > 9. c7t11d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@b,0 > 10. c7t12d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@c,0 > 11. c7t13d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@d,0 > 12. c7t14d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@e,0 > 13. c7t15d0 <HP-LOGICAL VOLUME-2.50-136.70GB> > /p...@0,0/pci8086,3...@1/pci103c,3...@0/s...@f,0 > > > prtconf > ====== > > pci, instance #0 > pci103c,330b (driver not attached) > pci8086,3408, instance #0 > pci103c,3245, instance #0 > sd, instance #1 > sd, instance #2 > sd, instance #3 > sd, instance #4 > sd, instance #5 > sd, instance #6 > sd, instance #8 > sd, instance #9 > sd, instance #10 > sd, instance #11 > sd, instance #12 > sd, instance #13 > sd, instance #14 > sd, instance #15 > pci8086,3409 (driver not attached) > > Any assistance is highly appreciated, > > Thanks, > Satya > > > ID7 is reserved for the SCSI host bus adapter by default. http://www.sun.com/blueprints/0800/scsi.pdf --Tim
_______________________________________________ driver-discuss mailing list driver-discuss@opensolaris.org http://mail.opensolaris.org/mailman/listinfo/driver-discuss