Euler, You want to reduce interference from regular clock events in your sampling.
On 9/7/07, 陶捷 TaoJie <[EMAIL PROTECTED]> wrote: > thank you, Menno. > > err, a further step... > if the firing profile probes always coincide with the regular clock-based > stuff, they will cause what? > I mean what will happen? Would it be serious? > > > Regards, > TJ > > > 2007/9/7, Menno Lageman <[EMAIL PROTECTED]>: > > 陶捷 TaoJie wrote: > > > in profile provider, using "profile-xxxhz" as the name > > > the probe name maybe > > > 97, 199, 499, 997, 1999, > > > 4001, 4999 HZ > > > > > > err... why are these numbers not multiples of 10/100/1000? > > > > > > > To skew the firing of the probes a bit so they don't always coincide > > with the regular clock-based stuff (which runs on multiples of > 10/100/1000). > > > > Menno > > -- > > Menno Lageman - Sun Microsystems - http://blogs.sun.com/menno > > > > > _______________________________________________ > dtrace-discuss mailing list > [email protected] > -- Just me, Wire ... Blog: <prstat.blogspot.com> _______________________________________________ dtrace-discuss mailing list [email protected]